Scientific journal
Научное обозрение. Медицинские науки
ISSN 2500-0780
ПИ №ФС77-57452

ERRORS AND COMPLICATIONS IN TREATMENT OF THE INJURED PERSONS WITH FEMORAL NECK FRACTURES USING TRANSOSSEOUS OSTEOSYNTHESIS

Allahverdiyev A.S. 1 Soldatov Yu.P. 1
1 Federal State-Financed Institution “Russian Ilizarov Scientific Center “Restorative Traumatology and Orthopedics” of the RF Ministry of Healthcare
There were analyzed errors and complications noticed in patients with femoral neck fractures. Patients were divided in groups. First group – femoral neck osteosynthesis by bundle of wires with the Ilizarov frame fixation was performed for injured persons (64 patients), second group – osteosynthesis by monolateral wire-half-pin device was used (23 patients). It was found out that using of the wire-half-pin devices, allowing to perform sufficient compression at the docking site, to insert fixators (wires, nails) through the bone fragments, to load hip joint and do not hinder in the gymnastics of the joint; for the treatment of patients with the femoral neck fractures, provides reduction of errors and complications during post-operative period in 4-8 times.